SafeDate™ Low Volume BUD Compliant Ophthalmic Dropper Bottle

1000 Bottles per box (100 packs of 10 EA) to be used with PF-P-02 caps

Catalog #: PF-S-01 Quantity per Box: 1000Prime Volume (mL): 1.5 mLProduct Features: , , ,

Preservative-free formulations can be crucial to protecting a patient’s eyes. Preservatives can cause allergic reactions, irritation and in some cases even eye damage.

Compounding pharmacies following the latest USP <797> standards must now comply with special beyond use dating rules for preservative free compounds. Typically, these compounds must be labeled to comply with a 24-hour room temperature / 72 hour refrigerated rules which require disposal of the medication after a patient opens the container. The SafeDateTM system allows pharmacies a simple and economical way to adhere to this standard.

Product pairs with PF-P-02 to make a complete sealed dropper.

Features:
• Removes need to add preservatives to the formulation, respects the ocular surface
• Patients can open the bottle and close the bottle after opening allowing for multiple uses.
• User-friendly and intuitive. A multi-dose dropper that most patients are used to.
• Calibrated drops mean precise dosing for a better adherence to treatment
• Simple two-piece system, no special equipment required for assembly. Bottle and cap are friction fit
• PF-P-02 cap is designed with tweezer grips for easy assembly.

Product contains:
100 – 10 packs of 1.5 mL strips (single pouched) – 1000 units total

Final release testing includes sterility and endotoxins
More detailed product information for this item is available through our FAQ page.

What final release testing is performed for these bottle products?

Test Method Component
Sterility Direct Transfer Method Embedded Spore Strip accredited to the ISO 17025 Bottle, Cap
Endotoxin/LAL ISO 17025 – (USP), General Chapter <85>, (USP), General Chapter <161>, Medical Devices Bottle, Cap
USP <788> Test Method 1 – Particulates Test Method Acceptance Criteria: Based on the methodology of USP <788> Bottle

 

All testing is performed by qualified third party testing labs contracted with MPS Pharma. The final measurements are all reported on our current Certificate of Analysis.


Why do you measure particulates to USP <788>?

Our bottles are most used for topical ophthalmic preparations in the form of eye drops. This is a form of extraocular application of medication to the eyes. Specific chapters in USP guidelines state as follows:

USP <771> Opthalmic Products – Quality Tests:

“Two general categories apply for product administration to the tissues in the eye. Intraocular administration includes all ophthalmic products that cross (penetrate) boundary tissue, such as the cornea and sclera. For subvisible content, USP guidance is followed. Products for intraocular use must comply with Particulate Matter in Ophthalmic Solutions <789>. Product for extraocular use must comply with Particulate Matter in Injections <788>.”

Both USP <788> and <789> are applicable to finished drug products; containers are not considered finished drug product. The testing MPS Pharma has performed on the bottles is based on the methodology of USP <788>, with particulate measurements reported for 10 um and 25 um sizes against limits reported on a per container basis.


Can I see a sample Certificate of Analysis that comes with this product?

If I open the pouch, will the bottle contents still be sterile?

Outside the bottle:

Once the pouch has been opened, then by the definition the outside of the bottle cannot be considered sterile, unless the pouch is opened in a controlled sterile environment.

Inside the bottle:

  • Inside of the bottle of an opened pouch is sterile and will remain sterile if pouches are opened in a clean and sterile environment. To maintain sterility, pouches should be handled and closed in the same controlled environment.
  • MPS does not own any specific drugs of its own, and as a result has performed the CCIT test with water. MPS bottles pass the Container Closure Integrity Testing (CCIT) as defined by USP <1207>.
  • Many clients of MPS have performed CCIT protocols against the bottle combined with their specific drugs and they have successfully passed.
  • CCIT is not a sterility test. The CCIT methodology evaluates the container’s ability to maintain a container closure system in protecting the internal contents against potential external contamination.

The passing of these tests provides additional confidence that no external contaminants can enter the closure system.


What is the drop size for these bottles?

Drop size is dependent on several factors including the product being dispensed and the technique in which it is dispensed. The best advice for customers is to test the dropper tip with the compounded product to determine its suitability in its application.

A general water reference point can be provided to our customers as a starting guideline:

Size(s) Drop Size
1 mL 42 ul +/- 5 uL


What are the bottles made of? Can more information be shared?

The bottle is composed of low-density polyethylene resin (LDPE). The cap itself is composed of polypropylene (PP).


Can I get a specification sheet of this item for my records?

See the attached document for the specification sheet


Our pharmacy follows USP <797> and it requires we use depyrogenated materials. Are your products depyrogenated? Do you have a Certificate of Analysis (C of A) stating such?

All MPS lots are tested for endotoxins (pyrogens) and will meet the materials requirements as defined in USP <797>. A detailed explanation of this can be found in this PDF link. All MPS C of As include measurements for these endotoxins.