SafeDate™ Low Volume BUD Compliant Ophthalmic Dropper Bottle
1000 Bottles per box (100 packs of 10 EA) to be used with PF-P-02 caps
Preservative-free formulations can be crucial to protecting a patient’s eyes. Preservatives can cause allergic reactions, irritation and in some cases even eye damage.
Compounding pharmacies following the latest USP <797> standards must now comply with special beyond use dating rules for preservative free compounds. Typically, these compounds must be labeled to comply with a 24-hour room temperature / 72 hour refrigerated rules which require disposal of the medication after a patient opens the container. The SafeDateTM system allows pharmacies a simple and economical way to adhere to this standard.
Product pairs with PF-P-02 to make a complete sealed dropper.
Features:
• Removes need to add preservatives to the formulation, respects the ocular surface
• Patients can open the bottle and close the bottle after opening allowing for multiple uses.
• User-friendly and intuitive. A multi-dose dropper that most patients are used to.
• Calibrated drops mean precise dosing for a better adherence to treatment
• Simple two-piece system, no special equipment required for assembly. Bottle and cap are friction fit
• PF-P-02 cap is designed with tweezer grips for easy assembly.
Product contains:
100 – 10 packs of 1.5 mL strips (single pouched) – 1000 units total
Final release testing includes sterility and endotoxins
More detailed product information for this item is available through our FAQ page.
What final release testing is performed for these bottle products?
Test | Method | Component |
Sterility | Direct Transfer Method Embedded Spore Strip accredited to the ISO 17025 | Bottle, Tip, Cap |
Endotoxin/LAL | ISO 17025 – (USP), General Chapter <85>, (USP), General Chapter <161>, Medical Devices | Bottle, Tip, Cap |
All testing is performed by qualified third party testing labs contracted with MPS Pharma. The final measurements are all reported on our current Certificate of Analysis.
Can I see a sample Certificate of Analysis that comes with this product?
See the following attached PDFs:
If I open the pouch, will the bottle contents still be sterile?
Once the pouch has been opened, then by the definition the parts cannot be considered sterile, unless the pouch is opened in a controlled sterile environment.
What is the drop size for these bottles?
Drop size is dependent on several factors including the product being dispensed and the technique in which it is dispensed. The best advice for customers is to test the dropper tip with the compounded product to determine its suitability in its application.
Different nozzle sizes are available that determine the nominal drop size. MPS Pharma always carries a standard size 2.4 mm in stock. The 2.4 mm tends to cover most compounding usage cases. Other sizes are available via a special-order request.
A general water reference point can be provided to our customers as a starting guideline:
Valve Version | Nominal Drop Size | Status |
1.6 mm | 28 uL | Special order |
2.0 mm | 33 uL | Special order |
2.4 mm | 40 uL | Standard Stock |
2.7 mm | 43 uL | Special order |
3.0 mm | 46 uL | Special order |
3.6 mm | 53 uL | Special order |
Our pharmacy follows USP <797> and it requires we use depyrogenated materials. Are your products depyrogenated? Do you have a Certificate of Analysis (C of A) stating such?
All MPS lots are tested for endotoxins (pyrogens) and will meet the materials requirements as defined in USP <797>. A detailed explanation of this can be found in this PDF link. All MPS C of As include measurements for these endotoxins.
Why do you measure particulates to USP <788>?
Our bottles are most used for topical ophthalmic preparations in the form of eye drops. This is a form of extraocular application of medication to the eyes. Specific chapters in USP guidelines state as follows:
USP <771> Opthalmic Products – Quality Tests:
“Two general categories apply for product administration to the tissues in the eye. Intraocular administration includes all ophthalmic products that cross (penetrate) boundary tissue, such as the cornea and sclera. For subvisible content, USP guidance is followed. Products for intraocular use must comply with Particulate Matter in Ophthalmic Solutions <789>. Product for extraocular use must comply with Particulate Matter in Injections <788>.”
Both USP <788> and <789> are applicable to finished drug products; containers are not considered finished drug product. The testing MPS Pharma has performed on the bottles is based on the methodology of USP <788>, with particulate measurements reported for 10 um and 25 um sizes against limits reported on a per container basis.
What are the bottles made of? Can more information be shared?
The bottle and tip itself are composed of low-density polyethylene resin (LDPE). These are the fluid contact surfaces. The cap itself is composed of polypropylene (PP) and can be considered a non-fluid contact surface.
A more detailed material profile is available to share with customers who complete a non-disclosure agreement.
Can I get a specification sheet of this item for my records?
See the attached document for the specification sheet